The XPR Automatic Balance is designed to enhance precision and efficiency in dispensing powders and liquids by automating the weighing process. This automation helps eliminate user errors and saves time during preparation of solutions and dilutions.

CategoryAutomated Powder & Liquid Dosing
IndustryPharma, Testing Labs, Academia
ReferenceBALANCE-XPR106DUHQ
Request a Quote →

Specifications

Adjustment
Internal (automatic/FACT)
Legal for Trade
No
Maximum Capacity
120 g;41 g
Readability
0.005 mg;0.002 mg
Repeatability (at 5% load)
0.005 mg
Repeatability, automated (at 5% load) – with closed doors
0.003 mg
Settling Time
2.5 s
Linearity deviation
0.1 mg
Dimensions
485 mm
Dimensions
426 mm
Dimensions
195 mm
Repeatability, typical
0.003 mg
Interfaces
USB-B (to device);RS232 (integrated / optional);USB-A (to device);Bluetooth (optional);Ethernet (LAN)
Price
$$$
Balance Type
Automatic Balance
Mettler's Top Pick
Yes
Family
Excellence
Recommended for Food QC
Yes
Compliance Options
Data Integrity;Log history (21 CFR Part 11 Compliant);Password protection;Log history (Basic Metadata)
Documentation Options
Printing;Basic Electronic Documentation;Automatic Documentation (21 CFR Part 11 Compliant)
Recommended for Biopharmaceutical
Yes
21 CFR Part 11 Compliant Weighing
Yes
Automation Options
Automated Powder Dispensing;Automated Workflows;Automated Liquid Dispensing
Balance Line
XPR
Minimum Weight (USP, 0.1%, typical)
4 mg
Automatic Static Detection
Yes
Level
Excellence $$$
Features
Automatic static detection;Automatic doors;Password protection;Leveling guidance;Automated dispensing;Supports 21 CFR Part 11 (LabX compatible);User management
Approved Balance
No
Recommended for
Pharma
Beta (Coarse range)
0.00000928 g
Alpha (Coarse range)
0.00000676 g
Beta (Fine range)
0.00000939 g
Alpha (Fine range)
0.00000726 g

Key features

  • Minimum weight (tolerance = 1%) – determined at 5% load, k = 2: 0.6 mg
  • Minimum weight (USP, tolerance = 0.10%) – determined at 5% load, k = 2: 6 mg
  • Typical Repeatability, automated (at 5% load) – with closed doors: 0.002 mg
  • Minimum weight automated (tolerance = 1%) – determined at 5% load, k = 2: 0.4 mg
  • Minimum weight automated (USP, tolerance = 0.10%) – determined at 5% load, k = 2: 4 mg
INQUIRY

Get a tailored quote for the Balance XPR106DUHQ.

Tell us the application, throughput, and any compliance requirements. An LDY account manager assigned to Pharma will respond within one business day.

Balance XPR106DUHQ
mettler-toledo· Automated Powder & Liquid Dosing
Balance XPR106DUHQ

Request a quote for this instrument

We'll get back to you within 1 business day with pricing, lead time, and installation options.